New Irish & European Standard I.S. EN 12566-3

Fig.1 CE Mark awarded to bioCycle™ on completion of EN 12566-3 testing.

Click here for a full set of results » ( coming soon )

I.S. EN 12566-3 is the new standard for wastewater treatment systems up to a population equivalent of 50. The bioCycle™ system underwent 38 weeks of testing in a EN 12566-3 accredited test facility to assess its treatment efficiency, structural behavior and water tightness. On successful completion of testing the bioCycle™ system was awarded the following CE mark.

Minimum treatment efficiency required to achieve a 10mg/l BOD5 & S.S. standard as required by Local Authorities?

BOD5
Biological Oxygen Demand
S.S
Suspended solids
Influent strength 258 mg/l 323 mg/l
Effluent quality 10 mg/l 10 mg/l
Minimum treatment efficiency 96.12% 96.90%

bioCycle™ treatment efficiency

BOD5
Biological Oxygen Demand
S.S
Suspended solids
Influent strength 258 mg/l 323 mg/l
bioCycle™ effluent quality * 6 mg/l 8 mg/l
bioCycle™ treatment efficiency 97.5% 97%
*Average results achieved during 38 week test period in an accredited test facility.

acreditations